An ambulant toilet is a cubicle built for people who can walk but have limited mobility, balance or strength. It sits inside the male and female washrooms, measures 900mm to 920mm wide under AS 1428.1, and has grabrails on both sides of a raised pan. It isn’t a wheelchair toilet.
KEY TAKEAWAYS
- An ambulant toilet is a standard washroom cubicle with grabrails on both sides, a 460mm to 480mm pan and a 700mm door.
- NCC 2025 clause F4D5(c) requires one for males and one for females at each qualifying bank of toilets.
- It never replaces an accessible unisex compartment.
- 5.5 million Australians, 21.4% of the population, had disability in 2022 (ABS).
Who is an ambulant toilet designed for?
The ABS Survey of Disability, Ageing and Carers counted 5.5 million Australians with disability in 2022, up from 17.7% of the population in 2018 to 21.4%. Plenty of them walk with a stick, crutches or a frame. They don’t need wheelchair space, but they do need something to hold.
Typical users include older people, people with arthritis or poor balance, and anyone recovering from surgery. The word comes from the Latin ambulare, to walk.
| An ambulant toilet serves people who can walk but need support, such as users of walking sticks, crutches or frames. It differs from an accessible toilet, which is sized for wheelchair users. The ABS counted 5.5 million Australians with disability in 2022, 21.4% of the population. |
When does the NCC require an ambulant toilet?
In any building required to be accessible, NCC 2025 clause F4D5(c) requires at least one ambulant cubicle for males and one for females at each bank of toilets holding one or more toilets in addition to an accessible unisex compartment. Both must comply with AS 1428.1.
The rule is per sex, so one unisex ambulant cubicle doesn’t satisfy it. Under the NCC’s signage clause D4D7(1)(d), the sign identifying an ambulant facility must also sit on its door.
| NCC 2025 clause F4D5(c) requires at least one ambulant sanitary compartment for males and one for females at each bank of toilets that holds one or more toilets besides an accessible unisex compartment. Each must comply with AS 1428.1, and clause D4D7(1)(d) places its identifying signage on the cubicle door. |
What are the ambulant toilet requirements under AS 1428.1?

Standards Australia’s overview of AS 1428.1:2021 confirms the standard sets layouts for accessible and ambulant toilets. For an ambulant cubicle, the core figures are a 900mm to 920mm width, 900mm clear in front of the pan, a 700mm clear door opening and a 460mm to 480mm seat height.
| Requirement | Ambulant cubicle |
|---|---|
| Cubicle width | 900mm to 920mm |
| Clear space in front of pan | 900mm minimum |
| Door clear opening | 700mm minimum |
| Grabrails | Both side walls, 800mm to 810mm above floor |
| Pan seat height | 460mm to 480mm |
| Signage | Braille and tactile, on the door (NCC D4D7) |
Our toilet cubicle dimensions guide sets these figures beside standard and accessible sizes, and exact panel sizes for each model sit in our technical data sheets.
| Under AS 1428.1:2021, an ambulant toilet cubicle is 900mm to 920mm wide, with at least 900mm clear in front of the pan, a 700mm minimum clear door opening, grabrails on both side walls 800mm to 810mm above the floor, and a pan seat height of 460mm to 480mm. |
Ambulant vs accessible toilet: what’s the difference?

An accessible unisex toilet is a separate room sized for wheelchair users, with 1900mm by 2300mm of circulation space under AS 1428.1. An ambulant toilet is a cubicle inside the male and female washrooms, about a third of that footprint.
| Feature | Ambulant toilet | Accessible unisex toilet |
|---|---|---|
| Main user | People who walk with difficulty | Wheelchair users |
| Location | Inside male and female washrooms | Separate unisex room |
| Size | 900mm to 920mm wide cubicle | 1900mm by 2300mm circulation space |
| Fixtures inside | Pan and grabrails | Pan, basin, shelf, sanitary disposal |
| Signage | Ambulant sign on the door | Left or right handed indicator |
Because ambulant cubicles sit in the same run as standard ones, they’re usually built from the same cubicle partitioning system. Grabrails and other washroom accessories are supplied through Complete Washrooms.
| An ambulant toilet is a 900mm to 920mm wide cubicle inside the male and female washrooms, built for people who walk with difficulty. An accessible unisex toilet is a separate room with 1900mm by 2300mm of circulation space for wheelchair users. NCC 2025 requires the ambulant cubicle in addition to the accessible compartment. |
Frequently asked questions
Can one unisex ambulant cubicle serve both sexes?
No. Clause F4D5(c) asks for at least one ambulant compartment for males and one for females at each qualifying bank of toilets. A single shared cubicle meets only half of that, so separate male and female washrooms each need their own.
Can an accessible toilet double as the ambulant toilet?
Not under the deemed-to-satisfy provisions. F4D5(c) requires ambulant cubicles at banks with one or more toilets in addition to the accessible unisex compartment, so the accessible room can’t count as one. Any alternative would need a performance solution, assessed by your building surveyor.
Does an ambulant toilet need braille signage?
Yes. NCC 2025 clause D4D7(1)(a) requires braille and tactile signage identifying each sanitary facility in an accessible building, and D4D7(1)(d) puts the ambulant sign on the cubicle door, designed to AS 1428.1.
Specify compliant ambulant cubicles
Rynat has manufactured commercial washroom partitions in Australia for more than 30 years, built to AS 1428.1 and NCC requirements. Browse our toilet partition range, request a quote, or talk to our team about your next fitout.